APC Back-UPS Pro BR900MI Line-interactive UPS 900VA/540W
Sponsored This site contains affiliate links for which we may receive compensation. More information
APC Back-UPS Pro 900VA/540W Line Interactive UPS, Tower, 230V/10A Input, 6x IEC C13 Outlets, Lead Acid Battery, LCD, AVR
569.00 AUD
Price updated on: 12-10-2025 21:04:39
569.00 AUD
Price updated on: 12-10-2025 21:04:39 Find other available options:
| Identifiers | |
|---|---|
| MPN | APC CA01889 |
| Dimensions / Weight | |
| Key Features | |
|
AC outlet types A list of the different AC power outlet or coupler types that a product supports, such as C13, C19, C20, Type F, Type G (BS 1363), NEMA 5‑15R, etc. Each entry represents a distinct electrical connector that can be used to supply power to the device.
|
C13 coupler |
|
Alarm Indicates whether the product includes an alarm feature that alerts the user when a relevant event occurs, such as door opening, movement, or other conditions requiring attention. The alarm can be audible, visual, or both, and its presence helps prevent energy loss and ensures safety.
|
On Battery |
| Audible alarm(s) | Yes |
|
Battery chemistry The chemical composition or classification of a battery, such as lithium‑ion, lithium‑polymer, nickel‑metal hydride, sealed lead acid, alkaline, zinc‑air, etc. It indicates the type of electrochemical reaction that stores and delivers energy in the device.
|
Lead Acid |
|
Display type The type of visual panel or display technology used in a product, such as LCD, LED, OLED, TFT, IPS, AMOLED, or analog. It indicates the underlying technology that determines image quality, color reproduction, power consumption and suitability for different use cases.
|
LCD |
|
Harmonized System HS code The Harmonized System (HS) code is a standardized numerical identifier used internationally to classify traded goods. It consists of up to six digits, where each pair of digits represents progressively more specific product categories. The HS code facilitates customs duties, trade statistics, and regulatory compliance by providing a common language for describing products across borders.
|
85078000 |
| Input frequency | 60 Hz |
|
Input voltage range The minimum and maximum electrical voltage that a device can safely accept from its power source, expressed in volts (V). It indicates the acceptable supply voltage range for both alternating current (AC) and direct current (DC) inputs, ensuring compatibility with local mains or battery supplies.
|
176 V AC 294 V AC |
|
Load capacity The maximum load that the product can safely support, expressed in a unit such as kilograms or pounds. The value may represent total capacity for the entire device or per drawer/section when applicable.
|
900 VA/540 W |
|
Maximum input operation voltage The highest electrical voltage that a device can safely accept from its power source, expressed in volts (V). It indicates the maximum supply voltage compatible with the product and is used to ensure proper operation across different regions and power standards.
|
294 V |
|
Maximum operating temperature The highest temperature at which a product can operate safely without risk of damage or performance degradation. Values are expressed in degrees Celsius (°C). This attribute helps users verify that the device will remain within its thermal limits during normal use.
|
40°C |
|
Minimum input operation voltage The lowest electrical voltage that the product is designed to accept from its power source, expressed in volts (V). It indicates the minimum mains or battery supply required for safe and reliable operation.
|
176 V |
|
Number of batteries The total count of individual batteries that are included with or required for the product. This value indicates how many separate battery units are supplied, needed, or supported by the device, allowing users to understand power requirements and replacement needs.
|
1 |
| Operating humidity | 0% - 95% |
|
Power plug The type of electrical power connector or plug used by the product, such as IEC, NEMA, BS1363, C14, C20, etc. It indicates which standard socket or coupler is required for connecting the device to a mains supply or other equipment.
|
C14 coupler |
|
Storage temperature The range of temperatures in which a device can safely operate without risk of damage or performance degradation. Values are expressed in degrees Celsius (°C) and may represent a single temperature, a minimum–maximum interval, or an average operating point.
|
-15°C - 45°C |
| Surge protection features | Network |
|
Sustainability certificates A list of environmental, safety or quality certifications that a product has obtained from recognized authorities. Typical entries include RoHS, ENERGY STAR, CE, WEEE, TCO Certified, FCC, and other industry‑specific standards.
|
Green Premium |
| UPS topology | Line-Interactive |
|
Waveform The shape of the electrical voltage or current produced by a power supply, expressed as a string such as "Sine", "Square", or "Triangle". It indicates how the output varies over time and affects noise levels, harmonic distortion, and compatibility with electronic equipment.
|
Sine |

APC is a brand that specializes in making high-quality, durable, and functional clothing and accessories for men and women. The brand is known for its simple and timeless designs, as well as its focus on quality and functionality. APC is a favorite among fashion-savvy individuals for its unique and stylish pieces.