000VA Liebert PSA Line-interactive 230V Tower UPS - 12M RTB

Sponsored  This site contains affiliate links for which we may receive compensation. More information
Find other available options:
Identifiers
Model Emerson PSA1500MT3-230U
MPN Emerson PSA1500MT3-230U
Dimensions / Weight
Key Features
AC outlet types
A list of the different AC power outlet or coupler types that a product supports, such as C13, C19, C20, Type F, Type G (BS 1363), NEMA 5‑15R, etc. Each entry represents a distinct electrical connector that can be used to supply power to the device.
IEC 320, C13 coupler
AC outlets
The total count of standard AC power sockets available on the device, such as a power distribution unit or surge protector. This value indicates how many separate appliances can be connected simultaneously.
8 AC outlet(s)
Audible alarm(s) Yes
Battery capacity
The total amount of electrical energy a battery can store, expressed as a numeric value with an appropriate unit such as mAh or Ah. It indicates how long the device can operate between charges and allows users to compare power supplies across products.
9 VAh
Battery recharge time 6 h
Battery technology
The chemical composition or classification of a battery, such as lithium‑ion, lithium‑polymer, nickel‑metal hydride, sealed lead acid, alkaline, zinc‑air, etc. It indicates the type of electrochemical reaction that stores and delivers energy in the device.
Sealed Lead Acid (VRLA)
Battery type
The chemical composition or classification of a battery, such as alkaline, lithium‑ion, NiMH, or lead‑acid. It indicates the energy storage technology used in the product and helps users identify compatibility with devices that require specific battery chemistries.
VRLA
Battery voltage
The electrical potential difference supplied to a battery or measured across its terminals, expressed in volts (V). It indicates the nominal operating voltage of the battery and is used to match power sources, chargers, and devices that require a specific voltage level.
12 V
Certification
A list of official certifications or compliance marks that the product has received from regulatory bodies, safety organizations, or industry standards groups. Each entry represents a distinct certification such as CE, FCC, RoHS, UL, or WEEE, and may include additional details like version numbers or specific test reports.
CE
Colour
The colour or combination of colours that a product is available in, expressed as common names such as "Black", "Silver" or comma‑separated lists like "Black, White". It indicates the visual appearance of the item for consumers.
Black
Cooling type
The method used to dissipate heat from a component or system, such as active cooling (fans or liquid loops), passive heat sinks, or no active cooling. It indicates whether the product relies on airflow, conduction, or other mechanisms to maintain safe operating temperatures.
Passive
Depth
The linear measurement of an object from front to back or top to bottom, expressed in a physical unit such as millimeters, centimeters, inches, etc. It indicates how deep the item is and can be used for fitting, compatibility, or spatial planning.
360 mm
Form Factor
Specifies the physical configuration or design of a product, such as ATX, Micro‑ATX, Mini‑ITX, tower, case with cover, etc. It describes how the device is built and what mounting or expansion options it supports.
Tower
Harmonized System HS code
The Harmonized System (HS) code is a standardized numerical identifier used internationally to classify traded goods. It consists of up to six digits, where each pair of digits represents progressively more specific product categories. The HS code facilitates customs duties, trade statistics, and regulatory compliance by providing a common language for describing products across borders.
85078000
Height
The vertical dimension of a product measured from its lowest to highest point. It is expressed in a physical unit such as millimetres, centimetres or inches and applies to any item where height is relevant, including books, electronics, furniture and other objects.
234 mm
Input frequency
The frequency of the alternating current supplied to a power supply or charger, expressed in hertz (Hz). It indicates the acceptable operating range for the electrical mains that powers the device, ensuring proper functionality and safety.
50/60 Hz
International Protection IP code
The IP (Ingress Protection) code indicates a product’s resistance to solids and liquids. It follows the standard two‑digit format (e.g., IP20, IP67), where the first digit represents protection against solid particles and the second against liquids. The code may include an ‘X’ to denote unknown protection for that category or multiple codes separated by commas for products offering different levels of protection in various configurations.
IP20
Maximum input operation voltage
The highest electrical voltage that a device can safely accept from its power source, expressed in volts (V). It indicates the maximum supply voltage compatible with the product and is used to ensure proper operation across different regions and power standards.
287 V
Minimum input operation voltage
The lowest electrical voltage that the product is designed to accept from its power source, expressed in volts (V). It indicates the minimum mains or battery supply required for safe and reliable operation.
160 V
Nominal input voltage
The electrical voltage that a product accepts from its power source, expressed in volts (V). It indicates the minimum and maximum supply voltages compatible with the device, covering both AC and DC inputs where applicable.
230 V
Number of batteries supported
The total count of battery units that a product can accommodate or use simultaneously. This value indicates how many separate batteries are required, optional, or compatible with the device, helping users understand power capacity and replacement options.
2
Number of output phases
The total count of electrical output phases that a power device or system provides. This value indicates how many separate phase conductors are available for delivering electricity, which is important for understanding the device’s compatibility with single‑phase or three‑phase power supplies and its ability to handle different load configurations.
1
Operating altitude
The range of altitudes (in meters) at which a product or component can operate reliably without performance degradation due to changes in atmospheric pressure, temperature, or other altitude‑related effects.
0 - 3000 m
Operating relative humidity
The range of relative humidity (in percentage) within which the product is designed to operate reliably. Values are expressed as a minimum–maximum interval such as "20 - 80 %" and indicate the acceptable environmental moisture level for optimal performance.
0 - 90%
Operating temperature
The range of temperatures in which a product can safely operate without risk of damage or performance degradation. Values are expressed in degrees Celsius (°C) and may represent a single temperature, a minimum–maximum interval, or an average operating point.
0 - 40 °C
Output Power
The electrical power that a device can deliver or consume, expressed in watts (W). It represents the actual power output under normal operating conditions and is useful for comparing performance across similar devices.
900 W
Output power capacity
The maximum electrical power that a device can deliver or consume, expressed in volt‑amps (VA). It represents the apparent power rating of the product and is used to compare capacity across similar equipment.
1500 VA
Output power factor
The ratio of real power to apparent power supplied by a device, expressed as a unitless number between 0 and 1. It indicates how efficiently the device converts electrical energy into useful work; higher values mean less reactive power consumption.
0.6
Package depth
The linear measurement from front to back or top to bottom of a product’s packaging, expressed in a physical unit such as millimeters, centimeters, inches, etc. It indicates how deep the packaged item is and can be used for fitting, compatibility, or spatial planning.
432 mm
Package Height
The vertical dimension of a product’s packaging measured from its lowest to highest point. It is expressed in a physical unit such as millimetres, centimetres or inches and helps customers assess how tall the package will be when stored or shipped.
352 mm
Package width
The horizontal measurement of a product’s packaging, expressed in a linear unit such as millimetres or inches. It indicates how wide the package is from one side to the other and helps customers assess fit for storage, shipping, or display.
238 mm
Power plug
The type of electrical power connector or plug used by the product, such as IEC, NEMA, BS1363, C14, C20, etc. It indicates which standard socket or coupler is required for connecting the device to a mains supply or other equipment.
C14 coupler
RoHS compliance
Indicates whether the product is manufactured in accordance with the RoHS (Restriction of Hazardous Substances) directive, which limits the use of certain hazardous materials in electrical and electronic equipment.
Yes
Safety
A list of safety and regulatory certifications that a product complies with, such as CE, UL, FCC, or other regional standards.
IEC/EN/AS 62040-1-1
Storage temperature
The range of temperatures in which a device can safely operate without risk of damage or performance degradation. Values are expressed in degrees Celsius (°C) and may represent a single temperature, a minimum–maximum interval, or an average operating point.
-15 - 40 °C
Surge energy rating
The amount of electrical energy, measured in joules (J), that a device can absorb during a surge event before failure. It indicates the level of protection against voltage spikes and is useful for comparing surge protectors, UPS units, and other power‑conditioning equipment.
570 J
Sustainability certificates
A list of environmental, safety or quality certifications that a product has obtained from recognized authorities. Typical entries include RoHS, ENERGY STAR, CE, WEEE, TCO Certified, FCC, and other industry‑specific standards.
RoHS
UPS topology Line-Interactive
USB port
Indicates the presence and quantity of USB connectors on a product. The value is typically an integer representing how many USB ports are available, regardless of type or version.
Yes
Waveform
The shape of the electrical voltage or current produced by a power supply, expressed as a string such as "Sine", "Square", or "Triangle". It indicates how the output varies over time and affects noise levels, harmonic distortion, and compatibility with electronic equipment.
Stepwise
Weight
The mass of the product expressed in a standard unit such as grams or kilograms. It represents how heavy the item is and can be used for shipping calculations, handling instructions, or consumer information.
12.6 kg
Width
The horizontal measurement of a product, expressed in a linear unit such as millimetres or inches. It indicates how wide the item is from one side to the other and is used for sizing, fitting, and compatibility purposes.
147 mm
Emerson