ONLINE UPS Systems ZINTO 800 VA Line-Interactive Power Supply with 8 AC Outlets
Sponsored This site contains affiliate links for which we may receive compensation. More information
Sponsored ONLINE USV-Systeme ZINTO 800 uninterruptible power supply (UPS) Line-I
294.38 GBP
Price updated on: 07-05-2026 09:52:06
294.38 GBP
Price updated on: 07-05-2026 09:52:06 | Identifiers | |
|---|---|
| MPN | ONLINE USV-SYSTEME Z800 |
| Dimensions / Weight | |
| Key Features | |
|
AC outlet types A list of the different AC power outlet or coupler types that a product supports, such as C13, C19, C20, Type F, Type G (BS 1363), NEMA 5‑15R, etc. Each entry represents a distinct electrical connector that can be used to supply power to the device.
|
C13 coupler |
|
AC outlets The total count of standard AC power sockets available on the device, such as a power distribution unit or surge protector. This value indicates how many separate appliances can be connected simultaneously.
|
8 AC outlet(s) |
|
Battery voltage The electrical potential difference supplied to or measured across a battery’s terminals, expressed in volts (V). It represents the battery’s nominal operating voltage and is used to match power sources, chargers, and devices that require a specific voltage level.
|
24 V |
|
Cables included A list of the cable types that are supplied with the product, such as USB, HDMI, VGA, DisplayPort, LAN (RJ‑45), SATA, audio or other relevant connectors.
|
Power load cable, USB cable |
| Cold start | Yes |
|
Colour The colour or combination of colours that a product is available in, expressed as common names such as "Black", "Silver" or comma‑separated lists like "Black, White". It indicates the visual appearance of the item for consumers.
|
Black |
| Display | LCD |
|
Ethernet LAN ports Represents the total count of Ethernet LAN (RJ‑45) interfaces available on a product. The value is an integer indicating how many physical Ethernet ports are present, regardless of speed or generation.
|
2 |
|
Harmonized System HS code The Harmonized System (HS) code is a standardized numerical identifier used internationally to classify traded goods. It consists of up to six digits, where each pair of digits represents progressively more specific product categories. The HS code facilitates customs duties, trade statistics, and regulatory compliance by providing a common language for describing products across borders.
|
85078000 |
| Input frequency | 50/60 Hz |
|
International Protection IP code The IP (Ingress Protection) code indicates a product’s resistance to solids and liquids. It follows the standard two‑digit format (e.g., IP20, IP67), where the first digit represents protection against solid particles and the second against liquids. The code may include an ‘X’ to denote unknown protection for that category or multiple codes separated by commas for products offering different levels of protection in various configurations.
|
IP20 |
|
Maximum input operation voltage The highest electrical voltage that a device can safely accept from its power source, expressed in volts (V). It indicates the maximum supply voltage compatible with the product and is used to ensure proper operation across different regions and power standards.
|
274 V |
|
Maximum output operation voltage The highest electrical voltage that a device can safely produce or deliver on its output terminals, expressed in volts (V). It indicates the maximum output level for power supplies, UPS units, and other equipment where the user may need to know the peak voltage available for connected loads.
|
240 V |
| Mean time between failures | 50000 h |
|
Minimum input operation voltage The lowest electrical voltage that the product is designed to accept from its power source, expressed in volts (V). It indicates the minimum mains or battery supply required for safe and reliable operation.
|
176 V |
|
Minimum output operation voltage The lowest electrical voltage that a device’s output can provide or operate at, expressed in volts (V). It indicates the minimum supply level required for the product to function correctly and helps users verify compatibility with power sources and accessories.
|
208 V |
| Noise Level | 45 dB |
|
Operating relative humidity The range of relative humidity (in percentage) within which the product is designed to operate reliably. Values are expressed as a minimum–maximum interval such as "20 - 80 %" and indicate the acceptable environmental moisture level for optimal performance.
|
0 - 90% |
|
Operating temperature The range of temperatures in which a product can safely operate without risk of damage or performance degradation. Values are expressed in degrees Celsius (°C) and may represent a single temperature, a minimum–maximum interval, or an average operating point.
|
0 - 40 °C |
|
Power plug The type of electrical power connector or plug used by the product, such as IEC, NEMA, BS1363, C14, C20, etc. It indicates which standard socket or coupler is required for connecting the device to a mains supply or other equipment.
|
C14 coupler |
|
RS-232 ports Represents the total number of RS‑232 serial communication ports available on a product. The value is an integer indicating how many RS‑232 connectors are present, regardless of version or configuration.
|
1 |
|
Safety A list of safety and regulatory certifications that a product complies with, such as CE, UL, FCC, or other regional standards.
|
EN62040-1 |
|
Serial interface type The type of serial communication interface supported by the product, such as RS‑232, RS‑485, RJ‑45, or SATA. It indicates which physical connectors and protocols are available for data exchange with other devices.
|
RS-232 |
| UPS topology | Line-Interactive |
ONLINE USV-SYSTEME







