APC AP8853 Power Distribution Unit (PDU) 42 AC Outlet(s) 0U Black

Sponsored  This site contains affiliate links for which we may receive compensation. More information

Sponsored American Power Conversion (APC) AP8853 Zero U Metered Rack PDU

716.99 USD
Price updated on: 01-07-2025 16:07:21
Identifiers
MPN APC 0731304277019
Dimensions / Weight
Key Features
AC input frequency
The frequency of the alternating current supplied to a power supply or charger, expressed in hertz (Hz). It indicates the acceptable operating range for the electrical mains that powers the device, ensuring proper functionality and safety.
50 - 60 Hz
AC outlet types
A list of the different AC power outlet or coupler types that a product supports, such as C13, C19, C20, Type F, Type G (BS 1363), NEMA 5‑15R, etc. Each entry represents a distinct electrical connector that can be used to supply power to the device.
C13 coupler,C19 coupler
AC outlets
The total count of standard AC power sockets available on the device, such as a power distribution unit or surge protector. This value indicates how many separate appliances can be connected simultaneously.
42 AC outlet(s)
Colour
The colour or combination of colours that a product is available in, expressed as common names such as "Black", "Silver" or comma‑separated lists like "Black, White". It indicates the visual appearance of the item for consumers.
Black
Input connection type
The type of electrical connector or inlet that a device uses to receive power, such as IEC C14, NEMA L6-20P, Schuko, or custom industrial plugs. It indicates the physical shape and pin configuration required for proper connection and compatibility with mains supplies.
IEC 309 32A 2P+E
Load capacity
The maximum load that the product can safely support, expressed in a unit such as kilograms or pounds. The value may represent total capacity for the entire device or per drawer/section when applicable.
7680 VA
Maximum input current per phase
The maximum electrical current that a device can safely draw from each phase of its power supply, expressed in amperes (A). It indicates the highest current level the product is designed to handle per phase and helps users select compatible power sources and ensure safe operation.
32 A
Monitoring
A list of electrical parameters that the product can monitor, such as current, power and voltage. Each item in the list represents a distinct parameter that the device is capable of measuring or reporting.
Current,Power,Voltage
Mounting
The physical configuration or method used to secure a product, such as clamp, bolt‑through, vertical, horizontal, rack mounting, freestanding, wall mounting, or other installation approaches.
Vertical
Nominal output voltage
The electrical potential difference that a device is designed to accept from its power source, expressed in volts (V). It represents the typical operating voltage for the product and helps users verify compatibility with local mains or battery supplies.
230 V
Operating relative humidity
The range of relative humidity (in percentage) within which the product is designed to operate reliably. Values are expressed as a minimum–maximum interval such as "20 - 80 %" and indicate the acceptable environmental moisture level for optimal performance.
5 - 95%
Operating temperature
The range of temperatures in which a product can safely operate without risk of damage or performance degradation. Values are expressed in degrees Celsius (°C) and may represent a single temperature, a minimum–maximum interval, or an average operating point.
5 - 45 °C
Output connections
The types and quantities of electrical outlets or connectors that a device provides for external equipment, such as power sockets (e.g., C13, C19, BS 1363) or other interface plugs. The value is expressed as a textual list indicating each connector type and the number of available ports.
36x IEC 320 C13 6x IEC 320 C19
Pdu types
A list of the types of power distribution units (PDUs) that a product can support or be part of, such as Metered, Basic, Switched, Managed, Monitored, and combinations thereof. Each entry represents a distinct PDU configuration that may provide features like metering, switching, monitoring, or management.
Metered
Power plug
The type of electrical power connector or plug used by the product, such as IEC, NEMA, BS1363, C14, C20, etc. It indicates which standard socket or coupler is required for connecting the device to a mains supply or other equipment.
IEC309
Rack capacity
The height of a device measured in rack units (U), where one U equals 1.75 inches (44.45 mm). The value is expressed as an integer such as "2U" or a numeric measurement with the unit, for example "3.5U" or "61.25 mm". This attribute indicates how many rack units a product occupies when installed in a standard server rack.
0U
Storage temperature
The range of temperatures in which a device can safely operate without risk of damage or performance degradation. Values are expressed in degrees Celsius (°C) and may represent a single temperature, a minimum–maximum interval, or an average operating point.
-25 - 65 °C
APC

APC is a brand that specializes in making high-quality, durable, and functional clothing and accessories for men and women. The brand is known for its simple and timeless designs, as well as its focus on quality and functionality. APC is a favorite among fashion-savvy individuals for its unique and stylish pieces.