| Identifiers | |
|---|---|
| Model | APC 2704822 |
| MPN | APC 2704822 |
| Dimensions / Weight | |
| Key Features | |
| Audible alarm(s) | Yes |
| Battery recharge time | 3 h |
|
Certification A list of official certifications or compliance marks that the product has received from regulatory bodies, safety organizations, or industry standards groups. Each entry represents a distinct certification such as CE, FCC, RoHS, UL, or WEEE, and may include additional details like version numbers or specific test reports.
|
C-tick,CE,EN 50091-1,EN 50091-2,EN 55022 Class A,GOST,IEC 60950,VDE |
|
Input connection type The type of electrical connector or inlet that a device uses to receive power, such as IEC C14, NEMA L6-20P, Schuko, or custom industrial plugs. It indicates the physical shape and pin configuration required for proper connection and compatibility with mains supplies.
|
IEC-320-C14 inlet |
|
Input frequency The frequency of the alternating current supplied to a power supply or charger, expressed in hertz (Hz). It indicates the acceptable operating range for the electrical mains that powers the device, ensuring proper functionality and safety.
|
50/60 Hz |
|
LED indicators A list of the functions or statuses that an LED indicator on a device can display, such as power status, activity, link, and other operational signals.
|
Yes |
|
Nominal input voltage The electrical voltage that a product accepts from its power source, expressed in volts (V). It indicates the minimum and maximum supply voltages compatible with the device, covering both AC and DC inputs where applicable.
|
230 V |
|
Non-operating altitude The altitude interval (in meters) at which a product or component ceases to function correctly due to environmental factors such as reduced atmospheric pressure, temperature changes, or other elevation‑related effects. The value is expressed as a minimum–maximum range and applies to any device that has documented limits for operation above or below certain heights.
|
0 - 15000 m |
|
Operating altitude The range of altitudes (in meters) at which a product or component can operate reliably without performance degradation due to changes in atmospheric pressure, temperature, or other altitude‑related effects.
|
0 - 3000 m |
|
Operating temperature range (T-T) The temperature interval, expressed in degrees Celsius (°C), within which a product can safely operate without risk of damage or performance degradation. Values may be presented as a single temperature, a minimum–maximum range (e.g., "0 - 70 °C"), or an average operating point.
|
0 - 40 °C |
|
Output connections The types and quantities of electrical outlets or connectors that a device provides for external equipment, such as power sockets (e.g., C13, C19, BS 1363) or other interface plugs. The value is expressed as a textual list indicating each connector type and the number of available ports.
|
6 x IEC 320 C13 1 x IEC Jumpers |
|
Output Power The electrical power that a device can deliver or consume, expressed in watts (W). It represents the actual power output under normal operating conditions and is useful for comparing performance across similar devices.
|
500 W |
|
Output power capacity The maximum electrical power that a device can deliver or consume, expressed in volt‑amps (VA). It represents the apparent power rating of the product and is used to compare capacity across similar equipment.
|
750 VA |
|
Source data-sheet The website or platform from which the product data was obtained, typically a commercial catalog or manufacturer site. It indicates where the specifications and details were sourced for reference or verification purposes.
|
Icecat.biz |
|
Surge energy rating The amount of electrical energy, measured in joules (J), that a device can absorb during a surge event before failure. It indicates the level of protection against voltage spikes and is useful for comparing surge protectors, UPS units, and other power‑conditioning equipment.
|
340 J |
|
Typical backup time at full load The duration a device can operate on its internal power source while running at full load before it needs to be recharged or connected to an external supply. It is expressed in minutes, hours, or other standard time units and applies to devices such as UPS systems, battery‑powered equipment, and similar appliances.
|
4.8 min |
|
Typical backup time at half load The average time a device can operate on its internal battery or backup power source when running at half of its maximum load, expressed in minutes, hours, or other standard time units.
|
16.4 min |
|
Weight The mass of the product expressed in a standard unit such as grams or kilograms. It represents how heavy the item is and can be used for shipping calculations, handling instructions, or consumer information.
|
13.2 kg |

APC is a brand that specializes in making high-quality, durable, and functional clothing and accessories for men and women. The brand is known for its simple and timeless designs, as well as its focus on quality and functionality. APC is a favorite among fashion-savvy individuals for its unique and stylish pieces.