Vertiv Liebert GXT5 uninterruptible power supply (UPS) Double-conversion (Online) 2 kVA 2000 W 8 AC outlet(s)

Sponsored  This site contains affiliate links for which we may receive compensation. More information
Identifiers
MPN Vertiv GXT5-2000IRT2UXLE
Dimensions / Weight
Key Features
AC outlet types
A list of the different AC power outlet or coupler types that a product supports, such as C13, C19, C20, Type F, Type G (BS 1363), NEMA 5‑15R, etc. Each entry represents a distinct electrical connector that can be used to supply power to the device.
C13 coupler, C19 coupler
AC outlets
The total count of standard AC power sockets available on the device, such as a power distribution unit or surge protector. This value indicates how many separate appliances can be connected simultaneously.
8 AC outlet(s)
Audible alarm(s) Yes
Battery recharge time 4 h
Battery technology
The chemical composition or classification of a battery, such as lithium‑ion, lithium‑polymer, nickel‑metal hydride, sealed lead acid, alkaline, zinc‑air, etc. It indicates the type of electrochemical reaction that stores and delivers energy in the device.
Sealed Lead Acid (VRLA)
Battery voltage
The electrical potential difference supplied to or measured across a battery’s terminals, expressed in volts (V). It represents the battery’s nominal operating voltage and is used to match power sources, chargers, and devices that require a specific voltage level.
12 V
Colour
The colour or combination of colours that a product is available in, expressed as common names such as "Black", "Silver" or comma‑separated lists like "Black, White". It indicates the visual appearance of the item for consumers.
Black
Display LCD
Efficiency
The efficiency rating expresses the percentage of input power that a product converts into useful output, indicating how well it uses energy compared to similar models. A higher value means less waste and lower operating costs.
95%
Harmonized System HS code
The Harmonized System (HS) code is a standardized numerical identifier used internationally to classify traded goods. It consists of up to six digits, where each pair of digits represents progressively more specific product categories. The HS code facilitates customs duties, trade statistics, and regulatory compliance by providing a common language for describing products across borders.
85078000
Input connection type
The type of electrical connector or inlet that a device uses to receive power, such as IEC C14, NEMA L6-20P, Schuko, or custom industrial plugs. It indicates the physical shape and pin configuration required for proper connection and compatibility with mains supplies.
C14
Input frequency 50/60 Hz
Input power factor
The ratio of real power to apparent power in an electrical system, expressed as a dimensionless number typically between 0 and 1. It indicates how effectively the device converts electrical energy into useful work; values close to 1 mean high efficiency.
0.99
International Protection IP code
The IP (Ingress Protection) code indicates a product’s resistance to solids and liquids. It follows the standard two‑digit format (e.g., IP20, IP67), where the first digit represents protection against solid particles and the second against liquids. The code may include an ‘X’ to denote unknown protection for that category or multiple codes separated by commas for products offering different levels of protection in various configurations.
IP20
Maximum input operation voltage
The highest electrical voltage that a device can safely accept from its power source, expressed in volts (V). It indicates the maximum supply voltage compatible with the product and is used to ensure proper operation across different regions and power standards.
288 V
Maximum output operation voltage
The highest electrical voltage that a device can safely produce or deliver on its output terminals, expressed in volts (V). It indicates the maximum output level for power supplies, UPS units, and other equipment where the user may need to know the peak voltage available for connected loads.
240 V
Minimum input operation voltage
The lowest electrical voltage that the product is designed to accept from its power source, expressed in volts (V). It indicates the minimum mains or battery supply required for safe and reliable operation.
115 V
Noise Level 58 dB
Nominal input voltage
The electrical voltage that a product accepts from its power source, expressed in volts (V). It indicates the minimum and maximum supply voltages compatible with the device, covering both AC and DC inputs where applicable.
230 V
Number of output phases
The total count of electrical output phases that a power device or system provides. This value indicates how many separate phase conductors are available for delivering electricity, which is important for understanding the device’s compatibility with single‑phase or three‑phase power supplies and its ability to handle different load configurations.
1
Operating altitude
The range of altitudes (in meters) at which a product or component can operate reliably without performance degradation due to changes in atmospheric pressure, temperature, or other altitude‑related effects.
0 - 3000 m
Operating relative humidity
The range of relative humidity (in percentage) within which the product is designed to operate reliably. Values are expressed as a minimum–maximum interval such as "20 - 80 %" and indicate the acceptable environmental moisture level for optimal performance.
0 - 95%
Operating temperature
The range of temperatures in which a product can safely operate without risk of damage or performance degradation. Values are expressed in degrees Celsius (°C) and may represent a single temperature, a minimum–maximum interval, or an average operating point.
0 - 40 °C
Output connections
The types and quantities of electrical outlets or connectors that a device provides for external equipment, such as power sockets (e.g., C13, C19, BS 1363) or other interface plugs. The value is expressed as a textual list indicating each connector type and the number of available ports.
IEC320 C13
Output Power
The electrical power that a device can deliver or consume, expressed in watts (W). It represents the actual power output under normal operating conditions and is useful for comparing performance across similar devices.
2000 W
Output power capacity
The maximum electrical power that a device can deliver or consume, expressed in volt‑amps (VA). It represents the apparent power rating of the product and is used to compare capacity across similar equipment.
2 kVA
Power protection features
A comma‑separated list of the electrical protection mechanisms built into a device, such as overcurrent, overload, short circuit, under voltage, and overheating safeguards. The attribute indicates which protective features are present to protect the equipment and connected components from abnormal power conditions.
Overload
Safety
A list of safety and regulatory certifications that a product complies with, such as CE, UL, FCC, or other regional standards.
IEC62040-1:2008, GS; UL1778, c-UL
Serial interface type
The type of serial communication interface supported by the product, such as RS‑232, RS‑485, RJ‑45, or SATA. It indicates which physical connectors and protocols are available for data exchange with other devices.
RS-232,RS-485
Storage temperature
The range of temperatures in which a device can safely operate without risk of damage or performance degradation. Values are expressed in degrees Celsius (°C) and may represent a single temperature, a minimum–maximum interval, or an average operating point.
-15 - 40 °C
Sustainability certificates
A list of environmental, safety or quality certifications that a product has obtained from recognized authorities. Typical entries include RoHS, ENERGY STAR, CE, WEEE, TCO Certified, FCC, and other industry‑specific standards.
RoHS, ENERGY STAR
Typical backup time at full load
The duration a device can operate on its internal power source while running at full load before it needs to be recharged or connected to an external supply. It is expressed in minutes, hours, or other standard time units and applies to devices such as UPS systems, battery‑powered equipment, and similar appliances.
3 min
Typical backup time at half load
The average time a device can operate on its internal battery or backup power source when running at half of its maximum load, expressed in minutes, hours, or other standard time units.
9 min
UPS topology Double-conversion (Online)
Waveform
The shape of the electrical voltage or current produced by a power supply, expressed as a string such as "Sine", "Square", or "Triangle". It indicates how the output varies over time and affects noise levels, harmonic distortion, and compatibility with electronic equipment.
Pure sine
Vertiv
Vertiv is a technology company that provides critical infrastructure for data centers, communication networks and commercial and industrial facilities. Their products and services help customers manage their energy use, optimize their operations and protect their business.